xGen Stubby Adapter and UDI Primers
CAT# PRODUCT SIZE STORAGE ¼ÒºñÀÚ°¡ ÁÖ¹®
10005921[IDT] xGen¢â Stubby Adapter and UDI Primer Pairs, Index 1-9696 rxn-·Î±×ÀÎ
10005922[IDT] xGen¢â UDI Primer Pairs, Index 1-9696 rxn-·Î±×ÀÎ
10005924[IDT] xGen¢â Stubby Adapter, 96 reactions96 rxn-·Î±×ÀÎ
10005976[IDT] xGen¢â Stubby Adapter and UDI Primer Pairs, Index 1-1616 rxn-·Î±×ÀÎ
10005975[IDT] xGen¢â UDI Primer Pairs, Index 1-1616 rxn-·Î±×ÀÎ
10005974[IDT] xGen¢â Stubby Adapter, 16 reactions16 rxn-·Î±×ÀÎ

Adapters for next generation sequencing

High quality adapters that meet the ever-expanding needs of researchers using NGS

Adapters are a key component of the next generation sequencing (NGS) workflow. Whether your project requires a basic adapter or a sophisticated design for higher accuracy, IDT has the products and expertise to deliver the right solution.

Regardless of the NGS instrument or application, IDT has been serving the needs of NGS scientists for over 10 years. We are recognized as the leader in adapter synthesis based on our experience in custom oligo manufacturing and our commitment to quality. Additionally, our NGS customers and partners benefit from:

  • A comprehensive adapter offering
  • Innovative designs
  • Trusted customer support
  • Complete customizability

Due to our leadership in NGS adapter synthesis, Illumina chose IDT as its partner to develop the next generation of index adapters to improve sample multiplexing. These adapters contain Illumina¡¯s unique dual indexes (UDIs) that mitigate sample misassignment due to index hopping. IDT manufactures UDI adapters for Illumina and is also licensed to sell your own custom designed adapters containing these UDI sequences. See the press release here.

Figure 1. Examples of adapter designs. A variety of NGS adapter designs are available. When selecting or designing adapters, consideration must be given to the intended application, multiplexing needs, accuracy requirements, and analysis methods.

Considerations when selecting an adapter design

IDT provides xGen Dual Index UMI Adapters, xGen Stubby Adapter and Unique Dual Index Primers, and a Custom Adapter Configurator tool that guides you through design of Custom NGS Adapters. Below we describe some of the design considerations you will want to take into account.

Sequences for specific NGS platforms: During library preparation, adapters are attached (by ligation, PCR, or tagmentation) to the fragments of each sample library. Adapters include platform-specific sequences for fragment recognition by the sequencer: for example, the P5 and P7 sequences (Figure 1) enable library fragments to bind to the flow cells of Illumina platforms. Each NGS instrument provider uses a specific set of sequences for this purpose. IDT manufactures adapters for all major NGS platforms.

Sample indexing: Sample indexes (or indices) enable multiple samples to be sequenced together (i.e., multiplexed) on the same instrument flow cell or chip. Each sample index, typically 6–10 bases, is specific to a given sample library and is used for de-multiplexing during data analysis to assign individual sequence reads to the correct sample. Adapters may contain single or dual sample indexes depending on the number of libraries combined and the level of accuracy desired. Illumina recommends using unique dual indexes (UDIs) as a method to mitigate errors introduced by index-hopping. UDIs are particularly important when using instruments with patterned flow cells, such as the NovaSeq system.

IDT provides several indexing options with its Custom NGS Adapters. These include both IDT and Illumina 8 and 10 base index series, as well as the ability to upload your own index files.

Molecular barcoding: Unique molecular identifiers (UMIs) provide the highest levels of error correction and accuracy. UMIs are short sequences, often with degenerate bases, that incorporate a unique barcode onto each molecule within a given sample library. UMIs have been shown to reduce the rate of false-positive variant calls and increase sensitivity of variant detection. By incorporating individual barcodes on each original DNA fragment, variant alleles present in the original sample (true variants) can be distinguished from errors introduced during library preparation, target enrichment, or sequencing. Any identified errors can be removed by bioinformatics methods before final data analysis. Adapters that contain UMIs, such as the xGen Dual Index UMI Adapters, are available with a UDI design for detection of low-frequency variants. IDT Custom NGS Adapters can also be configured with UMIs.

Adapter manufacturing: Stringent manufacturing methods are critical for producing high quality NGS adapters. Substandard manufacturing practices can lead to low purity adapters or adapter cross contamination, either of which will negatively impact sequencing results. The IDT proprietary TruGrade process uses state-of-the-art synthesis and purification methods, designed specifically for NGS adapters. IDT also offers GMP grade adapter manufacturing for clinical applications.

Choose IDT adapter products based on the flexibility your experimental workflow requires. Click on the xGen Dual Index UMI Adapters—Tech Access, the xGen Stubby Adapter and UDI Primers, or the Custom NGS Adapters headings in Table 1 to review product offerings. The Custom NGS Adapters provide a step-by-step tool to help you configure adapters best suited for your research.

Specifications xGen Dual Index UMI Adapters—Tech Access xGen Stubby Adapter and UDI Primers Custom NGS adapters
Configuration UDI-UMI UDI single index, combinatorial dual indexing, UDI, or UDI-UMI
Sample index length 8 base, non-redundant sample indexes 8 base, non-redundant sample indexes Configurable
Concentration 15 µM  15 µM (Stubby Adapter), 20 µM total (10 µM each Primer) 15 µM (Adapter), 20 µM total (10 µM each Primer)
Shipping container Tubes, plates  Tubes (Stubby Adapter), 96-well plates (UDI Primer Pairs) Tubes, plates, or single-use plates
Reactions Varies 1 reaction per primer pair Varies
Adapter modifications Available Methylated for bisulfite sequencing* Available
Illumina platform compatibility 2- and 4-color platforms 2- and 4-color platforms Designs for any application

* For bisulfite sequencing, see our FAQ for additional information.

»ç¿ë Èıâ
»ç¿ëÈıⰡ ¾ø½À´Ï´Ù.
»ç¿ëÈıâ ÀÛ¼º
gototop